REINSTALLING THE OUTER FAN BELT
1. To reinstall the outer fan belt you need to put the belt onto one pulley and guide it over
theotherpulleywithyourngerwhileturningthefanbelt.
2. Once the fan belt is on both pulleys, keep turning and the belt should center itself.
3. Reinstall the outer cover and tighten the knob screw.
4. With both fan belts installed and the covers in place, the unit can be checked.
5. With the spindle facing the workbench, start the motor and check the fan output bag
asitshouldfullyinateinafewseconds.
6. After testing, be sure to unplug the power cord, before reinstalling the grinding
wheel.